AIRSYS Cooling Equipment

MAXAIR

Brief:
MAXAIR is one of the air handing units in AIRSYS PowerOne solution. It provides appropriate air flow into data center, after the air exchanges the heat with the chilled water heat exchanger coils, to ensure that the indoor environment of the data center is always within the required range.

Product introduction

MAXAIR is one of the air handing units in AIRSYS PowerOne solution. It provides appropriate air flow into data center, after the air exchanges the heat with the chilled water heat exchanger coils, to ensure that the indoor environment of the data center is always within the required range.

MAXAIR is specially designed for high supply and return air temperatures, and maximizes the inlet and outlet water temperatures to 19/35°C, which change fundamentally the usage of free-cooling, and reduce the system water flow, deliver a datacenter with PUE<1.2 anywhere in the world.

Energy Efficiency

• Push the boundary
Maximize chilled water deleta temperture to 16℃, fundamentally change the usage of free-cooling, and significantly reduce the system water flow.
• Change the logic
The whole cooling system will be synergized and optimized toward IT load, and ambient condition, but not the temperature in the room, the system will always operate proactively and predictably, increase the reliability and reducing the energy cost.
• Adapt to new technology
Using the latest IoT, Cloud, AI, and ML technology, the monitoring and control system will give customer the full visibility of the performance, status and historical data of the system.

Modular Design

• Modular design, basic model is 67kW. multiple units can be grouped into different cooling capacities.
• Rapid deployment on site.
• Easy inventory management, bulk stock in advance, shorter the delivery time.
• Scalability reduce initial investment.
• Compact size, ease transportation, installation and service.
• Small footprint with high cooling density, absorbing up to 200kW of heat in only 1620mm of linear space.
• Modular design, fewer parts and components, easier maintenance.

Hot aisle containment

• Eliminate cool and hot air mixing, increase cooling capacity and efficiency
• Support higher-density server applications
• Eliminate data center hot spots
• CFD simulation, optimize air flow
• Data centers open space is a cold environment, create a cooler environment for workers

High Reliability and Serviceability

• 24*7 uninterruptible operation design.
• Highly safety performance guaranteed by functions and protections designed for the unit.
• 4 Levels of Password Protection.
• All routine maintenance is via the front and rear of the unit.

Intelligent Control system

• Highest protection against downtime, equipment damage and excess wear and tear.
• Touched screen interface offers the full visibility.
• AIRSYS NetOne Monitoring & Control for multiple units teamwork. integrated the latest technology of AI, ML and IoT to provide the monitoring and reliability for a more efficient operation of the cooling system.