AIRSYS Cooling Equipment

OPTIMA2

Brief:
OPTIMA2 is a CRAC unit designed for Data Center, Telecom and other Equipment rooms requiring uninterrupted temperature and humidity control. The unique modular structure will provide a super easy installation, operation and maintenance for either retrofit and new builds. The latest technology of variable speed inverter driven compressor, direct or indirect free cooling economizer guarantee the best ROI and lowest TCO on the market.

Product introduction

OPTIMA2 is a CRAC unit designed for Data Center, Telecom and other Equipment rooms requiring uninterrupted temperature and humidity control. The unique modular structure will provide a super easy installation, operation and maintenance for either retrofit and new builds. The latest technology of variable speed inverter driven compressor, direct or indirect free cooling economizer guarantee the best ROI and lowest TCO on the market.

p1.jpg

Energy Efficiency

Inverter compressor can adjust the speed constantly to maintain desired temperature level. It can achieve COP>14 with nominal cooling capacity @ AHRI360 test conditions. When the compressor is working at part-load, it can even achieve COP up to 19, 75% higher than that of the fixed speed compressor.

p2.jpg

Offer 2 options for energy saving: Direct Free Cooling and Refrigerant Pump, both of which can reduce the dependency on DX system, minimize DX system run hours, and reduce the energy comsumption.

EC fan, 60%-90% more efficient than old style fan.

Auto-control optimizes system performance

p3.jpg

Modular Design - Easy installation and Maintenance

Modular design, basic model is 40kW. multiple units can be grouped into different cooling capacities(20~200kW)

Rapid deployment on site

Easy inventory management, bulk stock in advance, shorter the delivery time

Scalability reduce initial investment

p4.jpg

Compact size, single module can be easily moved and can pass through the narrow stairs, corridor, and elevator.

Small footprint with high cooling density, the cooling density(cooling capacity per floor area) is as highe as 3.45kW/ft2

All routine maintenance is from the front of the unit, with easily removable access panels.

Modular design, fewer parts and components, easier maintenance.

p5.jpg

Vertical V-shape Condenser

• Vertical discharge condenser, least disruption from seasonal wind.

• Shoulder to shoulder installation, minimal footprint.

• 50% more condensers can be installed than horizontal discharge condensers

p6.jpg

Flexible Air Distribution Scheme

• Conventional down flow and up flow

• Cold or hot aisle containments

• Fan wall air distribution

p7.jpg

Intelligent Control System

• Highest protection against downtime, equipment damage and excess wear and tear.

• Touched screen interface offers the full visibility.

• AIRSYS NetOne Monitoring & Control for multiple units teamwork. integrated the latest technology of AI, ML and IoT to provide the monitoring and reliability for a more efficient operation of the cooling system.